Rainproof TB Series Time Switch IP-53

Rainproof TB Series Time Switch IP-53
Rainproof TB Series Time Switch IP-53

INTRODUCTION

  • When the time switch is used for loads exceeding the rated capacity, it is imperative that time switch be used in combination with one more magnetic contactors according to each load.
  • When the time switch is used with a heater, it is imperative that the load circuit be protected by a thermo-switch.

Product Description
SPECIFICATIONS
Item No :
  • TB35-RP
    Rated Voltage : 110V AC / 220V AC
    Voltage Tolerance : 85-120V / 170-240V
    Frequency : 50/60Hz (selectable)
    Driving Method : Synchronous motor
    Cycle : 24 hours
    OUTPUT- Circuit Quantity : 1 circuit
    OUTPUT- Switch construction : SPST
    OUTPUT- Manual ON/OFF : ON/AUTO/OFF switch
    OUTPUT- Contact Capacity - Resistive load : 250V AC 20A
    OUTPUT- Contact Capacity - Incandescent lamp : 10A
    OUTPUT- Contact Capacity - Inductive (cosφ) ≧0.7 : 12A
    OUTPUT- Contact Capacity - Motor (cosφ) ≧0.7 : 110V AC 750W, 220V AC 1500W
    OPERATION TIME SETTING - Present time setting : Turn the Minute control knob in the center clock.
    OPERATION TIME SETTING - Minimum unit : 15 Minutes / Unit
    OPERATION TIME SETTING - Minimum interval : 15 Minutes
    OPERATION TIME SETTING – No. of ON/OFF operations : 96 operations
    Working reserve time : --
    Ambient temperature : -10℃ ~ +50℃
  • TB35N-RP
    Rated Voltage : 100-240V AC
    Voltage Tolerance : 85-264 AC
    Frequency : 50/60Hz (common use)
    Driving Method : Quartz controlled stepping motor
    Cycle : 24 hours
    OUTPUT- Circuit Quantity : 1 circuit
    OUTPUT- Switch construction : SPST
    OUTPUT- Manual ON/OFF : ON/AUTO/OFF switch
    OUTPUT- Contact Capacity - Resistive load : 250V AC 15A
    OUTPUT- Contact Capacity - Incandescent lamp : 10A
    OUTPUT- Contact Capacity - Inductive (cosφ) ≧0.7 : 12A
    OUTPUT- Contact Capacity - Motor (cosφ) ≧0.7 : 110V AC 750W, 220V AC 1500W
    OPERATION TIME SETTING - Present time setting : Turn the Minute control knob in the center clock.
    OPERATION TIME SETTING - Minimum unit : 15 Minutes / Unit
    OPERATION TIME SETTING - Minimum interval : 15 Minutes
    OPERATION TIME SETTING – No. of ON/OFF operations : 96 operations
    Working reserve time : 100 hours
    Ambient temperature : -10℃ ~ +50℃
  • TB330-RP
    Rated Voltage : 100-240V AC
    Voltage Tolerance : 85-264 AC
    Frequency : 50/60Hz (common use)
    Driving Method : Quartz controlled stepping motor
    Cycle : 24 hours
    OUTPUT- Circuit Quantity : 1 circuit
    OUTPUT- Switch construction : SPST
    OUTPUT- Manual ON/OFF : ON /OFF switch
    OUTPUT- Contact Capacity - Resistive load : 250V AC 30A
    OUTPUT- Contact Capacity - Incandescent lamp : 25A
    OUTPUT- Contact Capacity - Inductive (cosφ) ≧0.7 : 12A
    OUTPUT- Contact Capacity - Motor (cosφ) ≧0.7 : 110V AC 1500W, 220V AC 3000W
    OPERATION TIME SETTING - Present time setting : Turn the Minute control knob in the center clock.
    OPERATION TIME SETTING - Minimum unit : 15 Minutes / Unit
    OPERATION TIME SETTING - Minimum interval : 30 Minutes
    OPERATION TIME SETTING – No. of ON/OFF operations : Standard 6 operations. Maximum 48 operations are possible.
    Working reserve time : 150 hours
    Ambient temperature : -10℃ ~ +50℃
CAUTIONS
  • For the first time, please charge battery first for till running (hear DI DA sound) before setting time.(TB35N-RP, TB330-RP only)
  • To set the correct time, turn the dial in the direction of arrow (clockwise) and set the present time.
  • Please observe the rated voltage and voltage tolerance of the time switches for adequate use.
  • If the load capacity exceeds the rating, an electromagnetic switch is required.